On-screen error message
8194
CPUID, Processor
Family are different
8195
Front Side Bus Speed
mismatch. System
Halted
8196
Processor Model are
different
8197
CPU Speed mismatch
8300
Baseboard
Management Controller
failed to Function
8301
Front Panel Controller
failed to Function
8305
Hotswap Controller
failed to Function
8420
Intelligent System
Monitoring Chassis
Opened
84F1
Intelligent System
Monitoring Forced
Shutdown
84F2
Server Management
Interface Failed
84F3
BMC in Update Mode
84F4
Sensor Data Record
Empty
84FF
System Event Log Full
Description
The processor type does not
match the value in the
installed processor [1, 2].
The front side bus speed
does not match the value in
the installed processor [1,
2].
The processor model does
not match the value in the
installed processor [1, 2].
The processor clock speed
does not match the value in
the installed processor [1,
2].
The baseboard
management controller does
not function.
The front panel controller
does not function.
The hot swap controller
installed on the SCSI back-
plane (HSBP) does not
function.
The top cover is not installed
correctly.
The system was forcibly
shut down.
A server management
interface failure occurred.
The baseboard
management controller is in
update mode.
There is no sensor data
record.
The event log is full.
Troubleshooting 6-7
Action
Securely install the processor.
Contact your sales representative
to replace the processor or system
board.
Install processors under the same
specification.
Contact your sales representative
to replace the system board.
Install the top cover correctly.
Confirm that the system starts
normally. If the system is in
abnormal state, contact your sales
representative to replace the
system board.
Contact your sales representative
to replace the system board.
Ask your sales representative for
maintenance.
Clear the event log by using the
BIOS SETUP utility. If the error is
not eliminated, contact your sales
representative to replace the
system board. The error message
is displayed periodically if
ESMPRO is not installed. The
event log must be cleared
periodically.