1. To set the EDID using menu:
MSD-804FD
↓ SET key
[FUNCTION SELECT]
EDID
↓ SET key
[EDID]
EDID DATA
↓ SET key
[IN1 EDID]
INTERNAL EDID
↓ SET key: Applies settings.
[EDID DATA]
NOW UPDATE...
[EDID]
EDID DATA
Note:
If you do not press the "SET" key, the EDID is not changed. Make sure to press the "SET" key.
The error message below is displayed for a second when the VFD screen moves from the sub menu to the
setup menu in the following cases:
- "OUTn MONITOR" is set for any input channel, and
- no display device is connected, or
- loading EDID fails.
OUT1A MONITOR
UNCONNECTED
If EDID cannot be updated pressing the "SET" key, the same message is displayed for a second as well.
If the error message is displayed, check the connection of the display device. If EDID can be loaded, EDID will
be updated automatically.
2. To set the EDID using commands:
@SED: Set EDID
@GED: Get EDID
Top
▲▼keys: Select "EDID".
▲▼keys: Select "EDID DATA".
▲▼keys: Select the EDID.
◄►keys: Select the desired input (IN1 to IN8).
The message is displayed for one second and then previous screen is
displayed automatically.
OUT1A MONITOR
EDID READ ERROR