① SWITCHING MODE
Sets and displays channel switching mode. Does not affect switching mode of the front panel.
V&A (switching video & audio simultaneously), VIDEO (switching only video), AUDIO (switching
only audio)
Selecting input channel (OFF, IN1 to IN8)
Selects video and audio output.
Orange: Video & Audio; Green: Only Video; Red: Only audio
DISPLAY POWER
Turns on/off connected display devices. No command is registered by factory default. To operate display's
power, register the command to this switch in "7.12.3 Control command association [COMMAND LINK]".
③ Cross point
Loads registered cross point.
④ Audio output level
Displays the current audio output level.
⑤ Audio output level (UP, DOWN)
Turns up/down the volume 1 [dB] per click.
MUTE
Turns on and off the mute function.
Red: MUTE ON; Black: MUTE OFF
⑦ COMMAND EXECUTE
Executes control commands assigned to COMMAND A to I. No command is registered by factory
as default. To execute control commands, register them to COMMAND A to I in advance by
following instructions in section "7.12.3 Control command association [COMMAND LINK]".
Buttons in which control command is registered are displayed in green. However, as each
command (A to I) has two planes (PLANE A and B), two commands are executed alternately if two
different commands are registered to plane A and B. If PLANE B is executed, the button is
displayed in green (PLANE A will be executed at the next click); if PLANE A is executed, the button
displayed in orange (PLANE B will be executed at the next click).
⑧ NAME EDIT
Edits names of "CROSS POINT", "AUDIO VOLUME," and "COMMAND EXECUTE". Click this
button, to open the window of "Window for editing names".
⑨ RELOAD
Acquires the latest information of the MSD from the MSD. (It can also be updated automatically by
setting "AUTO RELOAD TIMER", 11, below.)
⑩ AUTO RELOAD TIMER
Sets time interval to receive the latest information periodically and to refresh WEB browser window.
You can set the interval from 10 to 65535 seconds by 1 second. If you do not use this function, set
the interval to 0 second (factory default).