Input number, which is any of "1" to "9", but types and the numbers of selectable input connectors differ
*
depending on connected projectors.
3
*
Fan error, which is any of 0 to 2.
0: Error not detected or no detect error function
1: Warning
2: Error
4
*
Lamp error. Numbers and meanings are the same as those of the fan error status above.
5
*
Temperature error. Numbers and meanings are the same as those of the fan error status above.
6
*
Cover open error. Numbers and meanings are the same as those of the fan error status above.
7
*
Filter error. Numbers and meanings are the same as those of the fan error status above.
8
*
Other errors. Numbers and meanings are the same as those of the fan error status above.
9
*
Accumulated time of lamp, which is any of 0 to 99999. (For projectors that do not count the accumulated
time, the value is 0 at all times.).
10
*
Whether the lamp illuminates or not (0 or 1).
0: Not illuminate
1: Illuminates
For devices containing several lamps, accumulated time and lightning state for each device are replied
in sequence. For example, if a device containing three lamps, the following command is replied:
"%1LAMP=accumulated time 1(SP) lightning state 1(SP) accumulated time 2(SP) lightning state 2(SP)
accumulated time 3(SP) lightning state 3 CR"
11
Source number, which is input switchable. Any of 11 to 59 (Meaning is the same as that of "%INPT"
*
command). For devices containing several inputs, several statuses separated with a (SP) are sent. For
example, for a device having two inputs, "%1INST= source number1(SP)source number2CR" is sent.
12
*
20 to FF in hex; up to 64 characters.
13
*
20 to 7F in hex; up to 32 characters.
To check reply commands of PJLink commands, register reply commands by following tables above.
161