IDK msd-804fd User Manual page 142

Presentation switcher
Hide thumbs Also See for msd-804fd:
Table of Contents

Advertisement

[All connections: "RECEIVER" mode (Default)]
DIGITAL
DISPLAY
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OFF
POWER
MULTI
S WITCHE R
1
OUT1
2
OUT2
POWER
ON
3
OUT3
OFF
4
OUT4
MSD-804FD
IP address: 192.168.1.199
Factory default: All 8 connections are "RECEIVER" mode; the MSD can be controlled externally.
[Change connections 3 and 6 to "TRANSMITTER" mode]
DIGITAL
DISPLAY
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OFF
POWER
MULTI
S WITCHE R
1
OUT1
OUT2
2
POWER
ON
3
OUT3
OFF
4
OUT4
MSD-804FD
IP address: 192.168.1.199
To control peripheral devices, select "TRANSMITTER" mode.
Set the IP address and port number of the destination.
[Change connection 6 to "TRANSMIT" mode of "PJLink protocol"]
DIGITAL
DISPLAY
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
OFF
POWER
MULTI
S WITCHE R
1
OUT1
COMMAND
2
OUT2
POWER
ON
3
OUT3
OFF
4
OUT4
SWITCHING MODE
V&A
MSD-804FD
IP address: 192.168.1.199
If you use "PJLink protocol", the port number will be fixed at "4352".
Connection 1
Connection 2
Connection 3
Port No.: 1100
MSD-804FD
COMMAND
COMMAND
COMMAND
COMMAND
COMMAND
A
B
C
D
E
MENU/SET
COMMAND
PRESET LOAD
Connection 4
ESC
SWITCHING MODE
V&A
VIDEO
AUDIO
Connection 5
Connection 6
Port No.: 23
Connection 7
Connection 8
Port No.: 80
Connection 1
Connection 2
Port No.: 1100
Connection 3
MSD-804FD
COMMAND
COMMAND
COMMAND
COMMAND
COMMAND
A
B
C
D
E
MENU/SET
COMMAND
Connection 4
PRESET LOAD
ESC
SWITCHING MODE
V&A
VIDEO
AUDIO
Connection 5
Port No.: 23
Connection 6
Connection 7
Connection 8
Port No.: 80
Connection 1
Connection 2
Connection 3
Port No.: 1100
MSD-804FD
COMMAND
COMMAND
COMMAND
COMMAND
A
B
C
D
E
MENU/SET
COMMAND
Connection 4
PRESET LOAD
ESC
VIDEO
AUDIO
Connection 5
Port No.: 23
Connection 6
Connection 7
Connection 8
Port No.: 80
[Fig. 7.30] LAN operation mode
Communication command control
Communication command control
Browser control
Communication command control
Communication command control
Browser control
IP address:
Control peripheral devices
PJLink: OFF
Port No.: 1200
IP address:
Control peripheral devices
PJLink: OFF
Port No.: 1300
Control over communication command
Communication command control
Browser control
IP address:
Control peripheral devices
PJLink: ON
Port number: 4352
142
MSD-804FD User's Guide
PC
IP address: 192.168.1.1
PC
IP address: 192.168.1.1
192.168.1.197
DVD player
192.168.1.198
Projector
PC
IP address: 192.168.1.1
192.168.1.198
Projector

Advertisement

Table of Contents
loading

Table of Contents