INSTALLATION AND SETUP
2-14
Installation of the pedestal's conduit panel is
MANDATORY to avoid risk of electric shock causing
1. From the AC power source, route 3-phase wires, single-phase and ground wires
into one of the knock-out holes located on the pedestal's conduit panel. Use
appropriately sized strain relief connectors with the conduit panel, which will
ensure adequate environmental sealing, prevent cables from wear and being
accidentally torn out.
Use of the conduit panel is mandatory to prevent electric shock.
2. Connect the incoming AC ground lead directly to the frame ground stud on the
floor of the pedestal (Figure 2.18 or Figure 2.19). Secure with both washers and
nut provided, and make sure there are no other wires present at this stud.
Connect ground FIRST to reduce shock hazard from high leakage.
Figure 2.17. Connect Incoming Ground Wire (shown for pedestals manufactured
WARNING
bodily harm or even DEATH.
WARNING
prior to November 17, 2006)
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)