Open Projector For Access; Connect Ballast Rs-232 And Interlocks To Projection Head - Christie CP2000 User Manual

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
NOTE: For all cable connections, keep cable ties that have been trimmed at
manufacture, but remove temporary ties that are untrimmed and have "tails".
5-1)
Open both pedestal doors (Figure 2.5).
5-2)
From the projection head, a) open the rear side door on the operator's side,
and b) open the lamp door. See Figure 2.5.
Figure 2.5. Open projector for access
5-3)
BALLAST RS-232 CABLE:
Panel B (9-pin), routing through the small rectangular access hole in the
front underside of the projection head (Figure 2.6). A second connector on
Panel B is pre-connected to Panel C. Any third connector is a non-
functional spare.
5-4)
BALLAST INTERLOCK CABLE:
002007 to Panel C (9-pin), routing through the small rectangular access
hole in the rear underside of the projection head (Figure 2.6). A second
connector on Panel C is pre-connected to Panel B, and the remaining third
connector is a non-functional spare.
Figure 2.6. Connect Ballast RS-232 and Interlocks to Projection Head
NOTE: These cables also connect to the fire alarm interlock and dedicated outlet
(both pre-connected at manufacture).
5-5)
POWER CABLES TO HEAD:
(within the pedestal), connect both identical power cables 34-001992 to
INSTALLATION AND SETUP
Connect the ballast's RS-232 cable 34-002075 to
Connect the ballast's interlock cable 34-
From behind the main AC breaker panel
2-5