Section 2: Installation and Setup

2.6.1 Configuring the Ballast for Incoming AC

AC power levels vary from region to region throughout
the world, with 400 VAC common in some countries
(such as those in Europe and Asia), and 200 VAC
common elsewhere (such as in North America and
Japan). To accommodate both possibilities, the ballast
includes an internal Input Power Range Switch for
toggling to the level of AC available at the installation
site, i.e. either 200 or 400 VAC. The line cord plug must
also match.
From the factory, the breakers/power switches and line
cord are both set for 200 VAC use. Depending on where
they were last used, used/rented lamp power supplies
may be set to either, so check the status of the line cord
plug and breakers/power switches before attempting to
connect to AC. See instructions below.
1. A visual inspection of the plug indicates the status
for the 200 or 400 VAC. Change the ballast's plug
type necessary for your site, as a delta load with
safety ground has no neutral.
2. Remove the ballast cover to access and read the
Input Power Range Switch
3. Toggle the breakers/power switches left for use with
200 VAC supplies or right for 400 VAC supplies.
4. Attach the ground lug to Earth Ground.
5. Re-install the ballast cover.
See
Section 2.2 Quick Setup
2-22
Servicing should only be done
by a Christie accredited service
technician.
.
for further details.
Roadie HD+35K Setup Guide
020-100394-06 Rev. 1 (10-2013)