3.2
Power-up
Procedure
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
NOTE: This is a manual power-up procedure. Some cinema installations may include
an automation system that controls lamp ignition in conjunction with other theatre
variables such as house lights, audio, and the start of the feature from a digital media
storage device/server.
Do not attempt operation if the AC supply and pedestal are not
1. Make sure that the breakers at the
main wall panel for the CP are
ON
switched
.
2. At the operator's side of the
pedestal, set all CP2000 circuit
ON
breakers to
—these are main
AC (3-phase), the projection head
(2-phase), and internal outlets
MAIN AC
(single-phase). The
will be green if AC is present,
components such as fans and
power supplies will start up, and
the TPC will begin initializing.
3. When the TPC has initialized
(approx. 15-30 seconds, indicated
by a green circle in the left
corner), press the lamp button on
the TPC Main menu to ignite the lamp.
IF THE LAMP DOES NOT IGNITE:
If a safety interlock switch is open (such as when the lamp door is ajar), the
lamp cannot be struck—the TPC lamp button will be disabled until the
interlock problem is resolved. An alarm window will also appear on the TPC.
If the lamp fails to ignite even though the interlock system is OK, the projector
will automatically re-try ignition using 100% of the maximum power
acceptable for the installed lamp. If this re-try also fails, a new lamp is likely
needed.
NOTE: For complete power-up troubleshooting, see Section 7, Troubleshooting.
WARNING
within the specified voltage range.
light
Figure 3.2. Power-up Procedure