Connecting An Internal Cinema Server/Source; Connecting An Internal Non-Cinema Source - Christie CP2000 User Manual

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
IF INTERNAL
: Sources/servers are often rack-mounted in the projector rear,
with cabling routed directly to the underside of the projection head—see
Figure 2.24 and Figure 2.25 (shown are CP2000 models with internal outlet
for North America, etc. Not applicable to CP2000-S. Refer to the separate
CP2000-S Addendum for more information). Install as follows:
1. Remove the pair of rack protector posts from the rear of the pedestal.
2. Remove the required horizontal rack covers (security plates).
3. Rack-mount the desired equipment within the pedestal.
4. Re-install the pair of rack protector posts. Keep extra covers.
Do not modify any CP wiring or lead dress during installation, and make
sure the added device does not interfere with normal CP operation.
Power normally connects to the projector's internal outlet (208 VAC models)
or is hard-wired to the TB2 terminal block (400 VAC models). NOTE:
Internal power connection is not possible if incoming AC feed is 4-wire 3-
phase only, as the internal outlet or TB2 terminal has no power in this case.
Figure 2.23. Connecting an Internal Cinema Server/Source
Figure 2.24. Connecting an Internal Non-cinema (DVI) Source
NOTE: The DVI ports are single-link ports for single-link cable/connectors only.
Using as a dual-link pair requires a special adapter (not currently available).