INSTALLATION AND SETUP
2-16
342-456 VAC
(Europe, etc.)
If 3-phase and single-phase feeds (6-wire):
o Make sure ground wire is connected directly to the frame ground stud on
the pedestal floor. Attach no other wires here.
o Connect L and N @ 200-230 VAC (single-phase)
o Connect 1, 2, and 3 @ 342-456 VAC (3-phase)
If 3-phase with neutral fed from 3-phase (5-wire):
o Make sure ground wire is connected directly to the frame ground stud on
the pedestal floor. Attach no other wires here.
o Connect 1, 2, 3, and N @ 342-456 VAC (3-phase)
o No L available. Connect jumper from 1 to L.
If 3-phase only (4-wire):
This configuration is not possible. Use 5-wire or 6-wire only. Neutral is
required.
Ground (earth) connection is necessary for safety. Never
compromise safety by returning current through the ground.

Special Adjustments for Some AC Supplies

AC levels can vary depending on region. Check the following when installing.
NOTES: 1) Requires voltmeter for up to 400 VAC. 2) Consult the Interconnect
Drawing in pedestal.
JUMPER FROM IGNITER TERMINAL 2
2
located on terminal
connects to
are present (as it is for most countries). If you find your incoming AC is below 207
VAC, connect terminal
• If AC between terminals
(factory default).
• If AC between terminals
Refer to Figure 2.20.
:
WARNING
: As set from the factory, the igniter jumper
T2
. This configuration is used when 207-265 VAC
2
T1
jumper to
instead.
2
3
and
is 207-265, connect terminal
2
3
and
is 180-207, connect terminal
2
T2
to
2
T1
to
.
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)