INSTALLATION AND SETUP
2.3
Assembly and
Connection of
Components
Before You Begin
Projection Head
and Pedestal
2-2
These instructions describe how to:
•
mount the projection head on to the pedestal
•
position the projector relative to the port window and screen
•
connect pedestal-to-head cabling and cooling hoses
•
customize projector for CP2000i vs. CP2000h/S lamps
•
connect exhaust ducting and fill liquid cooling system
•
install lens and lamp
•
connect to power
QUALIFIED TECHNICIAN REQUIRED
For all installation steps! Modify no circuits or wiring.
You will require the following for installation:
•
Full understanding of all site requirements and characteristics
•
12" screwdrivers: Philips (magnetic) and flat
•
Assorted wrenches such as 7/8" and ¾"
•
Assorted Allen keys such as 3/16", 7/64", 5/32", and M3
•
3-phase 4-wire, 5-wire, or 6-wire connection of AC supply to Terminal Block 1
in pedestal (certified electrician required).
•
Heat extractor (such as inline centrifugal blower Elicent model# AXC 315B) or
roof extractor providing at least 600 CFM at 8" exhaust duct opening @ 600
watts or lower. NOTE: Mount at an external location.
•
Lamp and protective clothing / safety gear
•
Laptop computer with DCP Librarian software with Ethernet or standard RS-232
cable
•
Vapor-free "dustoff type" compressed air can
•
Latex lab gloves
•
Lens cleaning tissue and solution (see 6.3, Maintenance & Cleaning)
•
For CP2000-S Models – Refer to the Addendum for Installation and Use
provided.
1) Secure projection head to pedestal
• For cable connections, maintain cable ties that
have been trimmed, and remove those that are not.
5-1)
Roll the pedestal as close as possible to its permanent location, with its
front toe facing the port window wall.
5-2)
Inside the pedestal, at the rear of the top frame, turn the knob to extend the
safety prop above the pedestal frame—this "stop" will then elevate the rear
of the projection head until fingers are safely out of the way. See Figure
2.1, Step 1.
WARNING
• Requires at least 2 people.
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)