TPC Alarm Window 
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
A/D Macro
Formatter Board
(a.k.a. Formatter Interface Board)
Processor Board
Diagnostics Performed
DSP
FPGA Load
FPGA Code Valid
FPGA Initialize
FPGA McBSP XRDY
FPGA Done
FPGA Register Read/Write
Serial ID Chip
CLUT SRAM
Overlay Framestore SDRAM
Resizer FIR Chip
Resizer FIFO
Other
System Supervisor Module
Self Test
Ballast Communications
]
Can also be set to trigger a full-screen flashing red alarm window on the TPC. Note that if a DMD
temperature exceeds a certain factory-set threshold for at least 2 seconds, the lamp will automatically
shut down. Recovery requires that the DMD temperature fall to a safe factory-set threshold.
Safety interlock.
In addition to the status bar at the bottom of any TPC screen, a full-screen red alarm
window flashes if one of the alarm conditions shown in the left column of Table 3.2
is encountered. If a safety interlock fails, power will no longer reach the lamp (DC
output is stopped), and the lamp button on the TPC Main menu will be disabled.
See Table 3.2.
STATUS MENU ENTRIES
Detected/Not Detected
OK/Failed
OK/Failed
Figure 3.7. Flashing Alarm Window