Connect 2 Cooling Hose Ends; Secure Lamp Lead And 2 Igniter Wires - Christie CP2000 User Manual

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
IMPORTANT: Ball joint must move freely. If
necessary, hand tighten with 9/64" allen key.
With 3/16" allen key, secure the
BLACK
lamp lead and the 2 igniter harnesses to
the side of the connector nut.
IMPORTANT: Secure lamp lead FIRST on
connector, then remaining 2 igniter wires on TOP.
At this point, the lamp pre-wiring is complete.
Leave lamp accessible for now.
6) Connect 2 Cooling Hose Ends (Pedestal-to-Head)
During operation, a closed loop of flexible tubing circulates cooling liquid stored in
the pedestal to critical electronic components located in the front compartment of the
projection head (see Figure 2.14). Looking into the pedestal, the liquid will circulate
counterclockwise.
INSTALLATION AND SETUP
NEGATIVE (–)
Figure 2.13. Secure Lamp
Lead and 2 Igniter Wires
Shown for pedestals manufactured before Fall 2006
2-9