Figure 2.18. Connect Incoming Ground Wire (shown for pedestals manufactured
November 17, 2006 and after)
3. Refer to the Terminal Block 1 (TB1) Connections diagram provided on the inside
of the pedestal door (operator's side). As described for your model and site,
connect all available wires to the large terminal block (TB1) located in the
operator's side of the pedestal:
NOTE: 1) The Terminal Block 1 (TB1) described below accommodates up to 6 AWG
wire. 2) For proper torque, a flat screwdriver with 4-6mm blade is recommended. 3)
Make sure to refer to the Terminal Block 1 (TB1) Connections diagram located in the
pedestal.
180-235 VAC
(N. America, Japan, most of Central/South America, etc.)
If 3-phase and single-phase feeds (6-wire):
o Make sure ground wire is connected directly to the frame ground stud on
the pedestal floor. Attach no other wires here.
o Connect L and N @ 200-230 VAC (single-phase)
o Connect 1, 2, and 3 @ 180-235 VAC (3-phase)
If 3-phase with neutral fed from 3-phase (5-wire):
o Make sure ground wire is connected directly to the frame ground stud on
the pedestal floor. Attach no other wires here.
o Connect 1, 2, 3, and N @ 180-235 VAC (3-phase)
o No L available. Connect jumper from 1 to L.
If 3-phase only (4-wire):
o Make sure ground wire is connected directly to the frame ground stud on
the pedestal floor. Attach no other wires here.
o Connect 1, 2, and 3 @ 180-235 VAC (3-phase)
o No L or N available, so the internal outlet will not be functional.
INSTALLATION AND SETUP
:
2-15