Christie CP2000 User Manual page 126

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
CP2000h Pedestals
(3-phase plus single-phase)
38-813018-01/03 = 208 VAC ("DOMESTIC". North America and Japan, for example only.)
38-813018-02/04 = 400 VAC ("INTERNATIONAL". Europe and Asia, for example only.)
Nominal voltage
Absolute operating voltage range
Line frequency
Inrush current (max.)
note: does not include lamp
Current consumption per phase (max.) @
6.6 kW
Power consumption (max.)
Current rating (continuous) of 3-phase AC
input at breaker
BALLAST
Start-up voltage
Operating voltage range
Operating current range
Max. ripple
INTERNAL "CONVENIENCE AC"
Qty. & type of AC connector/receptacle
Maximum wire gauge for terminal blk.
Nominal voltage
(dependent on voltage connected to unit)
No. of phases, any region
Line frequency, any region
Power available (max.)
Current available, any region
** May be outlet (Leviton type 5320-WCP) or terminal block. Non-functional if 4-wire connection from AC.
CP2000i Pedestals
(3-phase plus single-phase)
38-813017-01/03 = 208 VAC ("DOMESTIC". North America and Japan, for example only.)
38-813017-02/04 = 400 VAC ("INTERNATIONAL". Europe and Asia, for example only.)
Nominal voltage
Absolute operating voltage range
Line frequency
Inrush current (max.)
note: does not include lamp
Current consumption per phase (max.) @
3.3 kW
Power consumption (max.)
Current rating of 3-phase AC input (max.)
at breaker
BALLAST
Start-up voltage
Operating voltage range
Operating current range
Max. ripple
INTERNAL "CONVENIENCE AC"
• 208 VAC (N. America / Japan)
• 400 VAC (Europe / Asia)
• 180-235 VAC (N. America / Japan)
• 342-456 VAC (Europe / Asia)
50 Hz – 60 Hz nominal
• 40 A (N. America / Japan)
• 30 A (Europe / Asia)
• 32 A @ 208 VAC (N. America / Japan)
• 16 A @ 400 VAC (Europe / Asia)
• 11 kVA (8.5 kW), all regions
• 40 A (N. America / Japan)
• 30 A (Europe / Asia)
80 – 107 VDC
24 – 41 VDC
75 – 170 A
5% @ 25°C
**
• 4 AC receptacles (N. America / Japan)
• 1 terminal block (Europe / Asia)
8 AWG
• 100 / 120 (N. America / Japan)
• 200 / 230 (Europe / Asia)
1
50 Hz – 60 Hz nominal
• 1200 W (N. America / Japan)
• 2300 W (Europe / Asia)
10 A
• 208 VAC (N. America / Japan)
• 400 VAC (Europe / Asia)
• 180-235 VAC (N. America / Japan)
• 342-456 VAC (Europe / Asia)
50 Hz – 60 Hz nominal
• 30 A (N. America / Japan)
• 20 A (Europe / Asia)
• 17.3 A @ 208 VAC (N. America / Japan
• 9.0 A @ 400 VAC (Europe / Asia)
• 6.6 kVA (5.0 kW), any region
• 30 A (N. America / Japan)
• 20 A (Europe / Asia)
80 – 107 VDC
20 – 32 VDC
50 – 120 A
5% @ 25°C
CP2000h Pedestals