Section 2: Installation and Setup

2.5.1 Configuring the Ballast for Incoming AC

AC power levels vary from region to region throughout
the world, with 400 VAC common in some countries
(such as those in Europe and Asia), and 200 VAC
common elsewhere (such as in North America and
Japan). To accommodate both possibilities, the ballast
includes an internal Input Power Range Switch for
toggling to the level of AC available at the installation
site, i.e. either 200 or 400 VAC. The line cord plug must
also match.
From the factory, the breaker/power switch and line cord
are both set for 200 VAC use. Depending on where they
were last used, used/rented lamp power supplies may be
set to either, so check the status of the line cord plug and
breaker/power switch before attempting to connect to
AC. See instructions below (see
1. A visual inspection of the plug indicates the status
for the 200 or 400 VAC. Change the ballast's plug
type necessary for your site, as a delta load with
safety ground has no neutral.
2. Remove the ballast cover to access and read the
Input Power Range Switch.
3. Toggle the breaker/power switch left for use with
200 VAC supplies or right for 400 VAC supplies.
4. Attach the ground lug to Earth Ground.
5. Re-install the ballast cover.
Refer to
Section 2.1.1 Quick Setup
2.6

Basic Image Adjustment

Assumes a single projector is powered up in its final location.
NOTE:
This initial optical alignment procedure is the foundation for optimizing your displays, ensuring that images
reflected from the DMDs are parallel to and well-centered with both the lens and screen. It should be
completed before adjusting the lens boresight.
Before you begin:
Properly position the projector relative to the screen (refer back to
Mounting).
2-20
Figure
2-22).
A Christie accredited service
technician is required.
for further details.
3.
Set switch
to match
incoming AC.
200
400
VAC
VAC
Figure 2-22 Setting up the Ballast
Section 2.2 Projector Position and
Roadie HD+35K Setup Guide
2.
Remove
ballast
cover.
1.
Plug must match
incoming AC:
200 or 400 VAC
Delta load plus
safety ground.
No neutral.
4.
Attach to Earth Ground
for RF/EMI Reduction
020-100394-02 Rev. 1 (01-2010)