Christie CP2000 User Manual page 142

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
Function Code / Examples
GPIO Assignments (GIO)
GIO I3 "LampOff"
GIO O3 "SystemHealth"
Image Scaling Enable/Disable (IMS)
(IMS 0)
Internal Test Pattern (ITP)
(ITP "RGB-12Bbit-Split Ramp")
(ITP"")
Lamp Changed (LPC)
(LPC "60123456" 100 "CDXL-20"
"Ignition Difficulty") or (LPC
"60123456" 100 "CDXL-20" 3)
Lamp History (HIS)
(HIS! 021 00001 "1234567" 00007
"2007/08/01 15:58" "Other-20"
00000 00000 00000 000 "Usage
Hours Exceeded")
Lamp Hours of Use (LPH)
(LPH 0528)
Lamp Hours Limit (LPL)
(LPL 750)
Lamp Intensity (LPI)
(LPI 12345)
(LPI?)
(LPI?s101)
(LP1!12345)
Description and Parameters
requires v2.7 or higher
Allows macros to be assigned to GPIs and GPOs
P1 = input # (1-5) or output # (1-5)
P2 = "Macro Name"
Predefined GPI macros:
• "LampOn"
• "LampOff"
• "DouserOpen"
• "DouserClosed"
• "AuxLensIn"
• "AuxLensOut"
• "Channel 101" through "Channel 116"
Predefined GPO macros:
• "System Health"
• "Lamp State"
• "Douser State"
• "Auxiliary Lens State"
Enables or disable image scaling
0 = disable
1 = enable
Enter "test pattern filename" to display pattern.
Enter "" to turn off the test pattern.
Records the serial number, hours logged on lamp, lamp
type and reason for change of the newly installed lamp,
thus resetting the lamp time to "0" for logging time. Serial
number = 32 characters max.
Valid Lamp Types
CDXL-20
CDXL-30
CDXL-45
CDXL-60
CXL-20
CXL-30
CXL-45
CXL 60
Other-16
Etc.
Lamp history describes lamps used in the projector. See
Messages With Multiple Parameters in this Appendix.
The #hours logged on the current lamp (0-9999).
The #hours that a lamp can be used before a warning
message appears. Range=0-20000 hours.
The light output level chosen for LiteLOC. Same intensity
for every channel requires LPB (Lamp Per Button) set to
"OFF".
NOTE: Specify desired channel with "S". If no "S" parameter is included,
the LPI setting will apply to the current channel when the "Lamp Per
Channel" checkbox is enabled, and to all channels when the checkbox is
cleared.
What is the current LiteLOC setting for this channel?
What is the LiteLOC setting for Channel 101?
The current LiteLOC setting is 12345
ASCII MESSAGES
Valid Change Reason
(can
be sent as number or text)
0 = ""
1 = "Usage Hours Exceeded
2 = "Light Level too Low"
3 = "Ignition Difficulty"
4 = "Light Unstable (flicker)"
5 = "Was Temporary Lamp"
6 = "Lamp Type Change"
7 = "Other"
B-3