For Your Information; History; System Status; System Status Messages - Christie CP2000 User Manual

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

ASCII MESSAGES
For Your Information (FYI) 
History (HIS) 
System Status (SST) 
B-10
FYI messages are generated and broadcast when an overall change in the projector's
status is detected. Each FYI message identifies the IP address of the TPC generating
the message, followed by a code for the change as well as one or more parameters of
descriptive details about what has changed.
NOTES: 1) Because FYI messages are gated by the Error Message Enable (EME)
control, disabling serial error message also disables FYI messages. 2) FYI messages
do not occur unless there is a Cine-IPM present.
A number of lamp histories are stored in memory, with the oldest discarded when
there is no more room. An accurate lamp history requires that the serial# for a new
lamp be recorded when the lamp is installed. HIS message parameters are:
P1 = Lamp order (oldest lamp installed = 001, next oldest = 002, etc.)
P2 = # of hours logged
P3 = Lamp serial#
P4 = #strikes
P5 = Installation date & time
P6 = Lamp type
P7 = Status Failed to Strike
P8 = Status Failed Restrike
P9 = Status Unexpected Offs
P10 = Life State
P11 = Change Reason
The SST message provides a variety of information about the current state of the
projector. The single broad-ranging request
return of a series of replies as if multiple requests had been sent. In each of these
replies, P1 explains the general content or topic of that reply, and P2 the individual
details. To obtain status for one topic only, specify the desired P1parameter
corresponding to that topic—for example, the request
projector information only. For a specific single-status inquiry, include both P1 and
P2 in the request—for example,
installed.
P1
If P1 = 0
0 = Model
General
1 = Serial Number
Projector
2 = Build date
Configuration
3 = Native Resolution
4 = N/A
5 = Lamp Power/Lamp Type
6 = Lamp Ballast I.D. (v 2.4c and up)
7 = Interface Board Serial#
8 = Processor Board Serial#
9 = Processor Board Type
10 = Interface Board Type
11 = Formatter Interface Type
12 = Formatter Board Type
If P1 = 1
0 = Power Status (0=Off, 1=On)

System Status

2 = LiteLOC (0=Off, 1=On)
3 = Lamp Expiry
4 = Lamp Hours
5 = Total Lamp Hours
(SST?)
(SST?4 3)
asks what version of SSM main software is
Table B.6. System Status Messages
P2
for all information triggers the
(SST?0)
will trigger general
Notes
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)

Hide quick links:

Advertisement

Table of Contents
loading