ASCII MESSAGES
B-6
Function Code / Examples
(SOR?)
(SOR!0)
Select Input (SIN)
(SIN 0 )
Simple Network Management (SNM)
(SNM 0 "trap IP address)
(SNM 0 OID)
Select Source Format (SRF)
(SRF "filename")
(SRF?)
(SRF!"1280x1024square")
Shutter Control (SHU)
(SHU 0)
(SHU 1)
Source Change (SRC)
System Status (SST)
Target Color Gamut (TCG)
(TCG "filename")
(TCG?)
(TCG!P7V2)
3D Controls (TDC)
(TDC 1)
(TDC 10 420)
Time & Date (TMD)
(TMD 2003 08 13 14 21 00)
(TMD! 2003 08 13 14 21 00)
Description and Parameters
1= Rear
2=Inverted Front
3=Inverted Rear
What is the current screen orientation setting?
Current screen orientation is normal front position
Select which projector (P1) and input (P2) to use.
P1 = Input
0= Input A (SMPTE/cinema)
1= Input B (SMPTE/cinema)
2= Dual SMPTE/cinema
3= DVI-A (non-cinema)
4= DVI-B (non-cinema)
5 = DVI Twin
6 = CineIPM input on DVI-A
7 = CineIPM input on DVI-B
8 = CineIPM input on DVI-Twin (10-bit)
9 = CineIPM channel on DVI-A
10 = CineIPM channel on DVI-B
11 = CineIPM channel on DVI-Twin (10-bit)
P2 = required for P1 = 6, 7
The input number (1-8) or channel number (1-25) of
CineIPM. Available for P1= 6 and P1 = 11 only
requires v2.7 or higher and TPC 60/66
Used for simple network management protocol setup
To disable specify "0.0.0.0"
OID is either 11273 or 25766
Select the stored source file defining incoming resolution
and desired aspect ratio for the current display.
What is the current source format?
Current source format filename is 1280x1024square.
Open or close the electronic "quick douser", where 0 =
shutter open and 1 = shutter closed
Same as CHA command
Method of reading projector information. See Messages
With Multiple Parameters later in this Appendix.
Select the stored target color gamut file to apply to the
current display.
What TCGD is currently in use?
The P7V2 TCGD is in use
Turn 3D controls on/off, or sets specific 3D controls.
Example shown: Set dark time to 420µs
For all other 3D controls, see Messages With Multiple
Parameters later in this Appendix.
Set/read the time and date in the projector's real-time
clock.
P1 = Year (yyyy)
P2 = Month (01-12)
P3 = Date (1-31, day of month)
P4 = Hour (0-23, 24hr clock)
LIT MAN USR CP2000