P3 Codes For “002” System Warning” Error Messages; P4 Codes - Christie CP2000 User Manual

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)
Component Code (P3)
68
Examples of Critical System Error (001) Messages
(65535 01002 ERR 001 "System Error: 0008 00001 Fan, Intake 1")
(65535 01002 ERR 001 "System Error: 000A 00001 Fan, Card Cage)
(65535 01002 ERR 001 "System Error: 0021 00001 Lamp, Failed to Ignite"
Table B.4. P3 Codes for "002" System Warning" Error Messages
Component Code (P3)
8010
8011
8012
8013
8014
8015
8016
8020
8021
8032
8033
8034
NOTE: System Warning messages can elevate to System Error messages if the problem is not fixed. In these cases,
the "8" in the original System Warning code will change to a "0" (see Table B.3).
Table B.5. P4 Codes
Examples (P4)
1500 (or lower)
056 (always °C)
00001
Examples of System Warning (002) Error Messages
(65535 01002 ERR 002 "System Warning: 8010 00051 Prism, Temperature Warning")
(65535 01002 ERR 002 "System Warning: 8020 00001 Lamp, Life Expired")
(65535 01002 ERR 002 "System Warning: 8032 00001 SSM Read Failed")
1
2
C Communication Failure
Prism, Temperature Warning
Temperature, DMD Red
Temperature, DMD Blue
Temperature, Integrator
Temperature, SSM
Temperature, Card Cage
Temperature, Ballast
Lamp, Life Expired
Lamp Failed to Ignite
SSM Read Failed
SSM Flash Write Attempted
Motor Calibrate Failed
(INCLUDED WITH SYSTEM WARNING ERROR MESSAGES ONLY)
Fan speed is 1500 RPM. Speed must be 1501 RPM or higher.
Temperature is 56°. Cool to within ranges shown in
There is no P4 data for this type of error
ASCII MESSAGES
Component
Component
Meaning
Table 3.1
.
B-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents