Summary Of Status Menu - Christie CP2000 User Manual

Hide thumbs Also See for CP2000:
Table of Contents

Advertisement

BASIC OPERATION
3-14
Table 3.1. Summary of Status Menu
Source
Projector Input
Signal
Cine-IPM
(not applicable for CP2000 projectors)
Power
Input and Channel
Signal
Standby
OSD
Environment
Projector Hours
Total Lamp Hours
Lamp
Current
Voltage
Power
Footlamberts
LiteLOC
Interlocks
Lamp Fan
(rear of projector)
Extractor Fan
(for ducting to outside world)
Lamp Door
(louvered lamp door)
Auxiliary
(fire alarms or automation, typically)
Tamper
(projector lid)
Temperatures (°C or °F) ]
Card Cage
DMD – Blue
DMD – Red
Integrator
Prism
SSM
Fan Speeds *
Fan #1 ("Intake #1")
Fan #2 ("Intake #2")
Card cage
LAD
Built-in Self Test
NOTE: If any of the following indicators are "red", service may be needed.
General
System
Power-up Self Test
Security Lock Integrity
I
2
C
Interface Board
Diagnostics Performed
ARM
FPGA Load
FPGA Code Valid
FPGA Initialize
FPGA No-Load Jumper
FPGA Done
FPGA Register Read/Write
UART 0
UART 1
I
2
C
Ethernet
Synchronous Serial Port
File System
GPI Macro
STATUS MENU ENTRIES
Source connection (location) of current signal
Vert. Freq.
On/off
Source connection (location) and channel#
Hor. & Vert. Freq. of current source
On/off
(NOTE: lamp remains on regardless)
On/off screen display of Cine-IPM menus
#Hours powered up with TPC communicating
#Hours logged for all lamps ever installed
#Hours logged on current lamp
Lamp current (#amps)
Lamp voltage (#volts)
Lamp power (#watts)
Footlamberts
(interpolated from min/max calibration)
On/Off/At Maximum Power
Critical safety and/or operation monitoring
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure triggers an alarm window and
stops CineLink
®
2 -encrypted cinema processing.
Critical internal temperatures in °C or °F
55-69°C=warning
50-54°C=warning
50-54°C=warning
95-104°C=warning
70-74°C=warning
55-59°C=warning
Speed (RPMs) of 4 internal cooling fans
RPMs of 1
st
primary fan (exhaust side of proj.)
RPMs of 2
primary fan (exhaust side of proj.)
nd
RPMs of electronics card cage fan
RPMs of laminar airflow device for DMDs
≥70°C=critical
≥55°C=critical
≥55°C=critical
≥105°C=critical
≥75°C=critical
≥60°C=critical
LIT MAN USR CP2000
020-100032-04 Rev. 1 (03/14)

Hide quick links:

Advertisement

Table of Contents
loading