BASIC OPERATION
3-14
Table 3.1. Summary of Status Menu
Source
Projector Input
Signal
Cine-IPM
(not applicable for CP2000 projectors)
Power
Input and Channel
Signal
Standby
OSD
Environment
Projector Hours
Total Lamp Hours
Lamp
Current
Voltage
Power
Footlamberts
LiteLOC
Interlocks
Lamp Fan
†
(rear of projector)
Extractor Fan
†
(for ducting to outside world)
Lamp Door
†
(louvered lamp door)
Auxiliary
†
(fire alarms or automation, typically)
Tamper
(projector lid)
Temperatures (°C or °F) ]
Card Cage
DMD – Blue
DMD – Red
Integrator
Prism
SSM
Fan Speeds *
Fan #1 ("Intake #1")
Fan #2 ("Intake #2")
Card cage
LAD
Built-in Self Test
NOTE: If any of the following indicators are "red", service may be needed.
General
System
Power-up Self Test
Security Lock Integrity
I
2
C
Interface Board
Diagnostics Performed
ARM
FPGA Load
FPGA Code Valid
FPGA Initialize
FPGA No-Load Jumper
FPGA Done
FPGA Register Read/Write
UART 0
UART 1
I
2
C
Ethernet
Synchronous Serial Port
File System
GPI Macro
STATUS MENU ENTRIES
Source connection (location) of current signal
Vert. Freq.
On/off
Source connection (location) and channel#
Hor. & Vert. Freq. of current source
On/off
(NOTE: lamp remains on regardless)
On/off screen display of Cine-IPM menus
#Hours powered up with TPC communicating
#Hours logged for all lamps ever installed
#Hours logged on current lamp
Lamp current (#amps)
Lamp voltage (#volts)
Lamp power (#watts)
Footlamberts
(interpolated from min/max calibration)
On/Off/At Maximum Power
Critical safety and/or operation monitoring
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure also triggers an alarm window
OK/Failure.
Failure triggers an alarm window and
stops CineLink
®
2 -encrypted cinema processing.
Critical internal temperatures in °C or °F
55-69°C=warning
50-54°C=warning
50-54°C=warning
95-104°C=warning
70-74°C=warning
55-59°C=warning
Speed (RPMs) of 4 internal cooling fans
RPMs of 1
st
primary fan (exhaust side of proj.)
RPMs of 2
primary fan (exhaust side of proj.)
nd
RPMs of electronics card cage fan
RPMs of laminar airflow device for DMDs
≥70°C=critical
≥55°C=critical
≥55°C=critical
≥105°C=critical
≥75°C=critical
≥60°C=critical
LIT MAN USR CP2000