8 ) Setting Exposure Amount - Kyocera Mita DC-2560 Service Manual

Table of Contents

Advertisement

1AH

( 8 ) Setting exposure amount

Perform the following adjustment when the main PCB and/or the drum is replaced.
Adjust for both normal and photo modes.
Precautions
• Check that the developer density is correct.
• Check that the halogen lamp has not deteriorated.
• Clean the optical unit.
• Never touch VR601, VR602 and VR603 on the Composite PCB.
• Setting method 1 of the simulation 24
(When NTC (new test chart) or NPTC (newspaper test chart) is used.)
<Mode setting sequence>
3-3-54
Start
Set mode 2 (manual mode Exp.4).
Set mode 1 (manual mode Exp.1).
Set mode 4 (manual mode Exp.7-
2).
Set mode 3 (manual mode Exp.7).
Set mode 6 (photo mode Exp.4).
Set mode 5 (photo mode Exp.1).
Set mode 7 (photo mode Exp.7).
End