Installing The Original Size Sensor (Optional) - Kyocera Mita DC-2560 Service Manual

Table of Contents

Advertisement

1AH
1AH

3-1-5 Installing the original size sensor (optional)

• Parts required for the installation
Two original size sensors 115 (P/N 33912230)
Two original size sensors 60 (P/N 33427430)
Original size sensor relay wire (P/N 34827140)
Two wiring bands with snap (P/N M2107120)
Four M3 × 5 bind bronze screws (P/N B1303050)
<Procedure>
1. Remove the upper right cover and remove the contact glass.
2. Remove the screw and remove the optical unit wire cover.
3. Connect the two original size sensors 115 and also the two original size sensors 60
to the original size sensor relay wire.
* Connect original size sensors 115 to the connectors of the two short relay wires of
the original size sensor relay wire, and the original size sensors 60 to the
connectors of the two long relay wires of the original size sensor relay wire.
Original size sensor 115
3-1-20
Optical unit wire cover
Figure 3-1-24
Original size sensor relay wire
2
Original size sensor 60
Figure 3-1-25
Original size sensor 115
1
Original size sensor 60
3
4

Hide quick links: