1AH
Problem
Causes/check procedures
(5)
Defective registration switch.
The misfeed
indicator for the
paper feed or
conveying
section lights
The registration clutch
during copying.
malfunctions.
Electrical problem with the
registration clutch.
The upper and lower
registration rollers do not
contact each other.
The upper and lower
registration roller cleaner
has deteriorated.
The feed unit rollers and the
right feed pulley do not
contact each other.
(6)
The registration clutch
The misfeed
malfunctions.
indicator for the
Electrical problem with the
paper
registration clutch.
conveying
section lights
The upper and lower
during copying.
registration rollers do not
contact each other.
The upper and lower
registration roller cleaner
and have deteriorated.
The feed unit rollers and the
right feed pulley do not
contact each other.
Broken eject switch
actuator.
Defective eject switch.
3-6-16
Corrective measure
If CN2-18 on the MPCB remains low
when the registration switch is turned
on while 5 V DC is present at CN2-17
on the MPCB, replace the registration
switch.
Check and remedy.
Check (see page 3-6-35).
Check and remedy (replace the
pressure springs if deformed) .
Check (see page 3-3-26).
Check and remedy.
Check and remedy.
Check (see page 3-6-35).
Check and remedy (replace the
pressure springs if deformed) .
Check (see page 3-3-24).
Check and remedy.
Check and replace the eject switch if
the actuator is broken.
If CN11-9 on the MPCB remains low
when the eject switch is turned on and
off while 5 V DC is present at CN11-8
on the MPCB, replace the eject
switch.
Need help?
Do you have a question about the DC-2560 and is the answer not in the manual?