Place the MTC on the contact
glass and select mode 4 with the
exposure adjustment keys.
Press the interrupt key.
Press the print key to make a test
copy. (Test copy is executed with
the image of the EXP.7-2)
Is the copy
image correct? *
Press the stop/clear key.
Exit simulation mode.
*4: 5 of A1 disappears and 6 reappears slightly or disappears.
C
· · · · · ·
· · · · · ·
No
4
Yes
End
A1
1
: 1 of A1 disappears.
2
: 2 of A1 disappears.
3
: 3 of A1 disappears.
4
: 4 of A1 disappears.
5
: 5 of A1 disappears.
6
: 6 of A1 reappears
slightly or disappears.
Figure 3-3-62-5
The current setting is displayed.
Press the print key.
The new setting is stored.
The copier enters ready mode.
Change the setting using the zoom
key.
* Setting range: 102-242
Reference: 187
* Increasing the value makes the image lighter,
and decreasing it makes the image darker.