2 ) Adjusting Tension Of The Scanner Drive Belt - Kyocera Mita DC-2560 Service Manual

Table of Contents

Advertisement

1AH

( 2 ) Adjusting tension of the scanner drive belt

Replace the scanner wire, scanner drive motor, or scanner drive belt as follows.
Procedure
1. Loosen the two screws.
2. Move the scanner drive motor assembly within long hole and adjust tension not so
as to break the scanner drive belt tooth.
3. Tighten the two screws.
4. Make operation check and readjust, if any.
3-3-104
Screw
Scanner drive belt
Figure 3-3-99