Installing The Key Counter (Optional) - Kyocera Mita DC-2560 Service Manual

Table of Contents

Advertisement

1AH
1AH

3-1-3 Installing the key counter (optional)

• Parts required for the installation
Key counter set (P/N 66069780)
Key counter socket (P/N 41529210)
Contents of the set:
Key counter cover (P/N 66060010)
Key counter cover retainer (P/N 66060020)
Key counter retainer (P/N 66060030)
Key counter mount (P/N 66060040)
Four M4 × 6 bronze TP-A screws (P/N B4304060)
Two M4 × 10 bronze TP-A screws (P/N B4304100)
One M4 × 6 chrome TP-A screw (P/N B4104060)
Two M3 × 6 bronze flat-head screws (P/N B2303060)
One M3 bronze nut (P/N C1303000)
<Procedure>
1. Fit the key counter socket to the key counter retainer with the two screws.
2. Fit the key count mount to the key counter cover with two screws, and attach the
retainer to the mount with two screws.
M4 × 6 screws
(B4304060)
Nut M3 (C1303000)
M3 × 6 flat-head screws (B2303060)
3-1-14
Key counter retainer (66060030)
M4 × 6 screw (B4104060)
Key counter socket (41529210)
Figure 3-1-17
Key counter mount (66060040)
Key counter cover
(66060010)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc-2060