1AH
Problem
(8)
Defective MPCB.
The scanner
fan motor 1
does not
operate.
(9)
Broken scanner fan
The scanner
motor 2 coil.
fan motor 2
Poor contact in the
does not
scanner fan motor 2
operate.
connector terminals.
Defective MPCB.
(10)
Broken paper
The paper
conveying fan motor
conveying fan
coil.
motor does
Poor contact in the
not operate.
paper conveying fan
motor connector
terminals.
Defective MPCB.
(11)
Broken upper lift
The upper lift
motor coil.
motor does
Poor contact in the
not operate
upper lift motor
(C250).
connector terminals.
Defective MPCB.
(12)
Broken lower lift
The lower lift
motor coil.
motor does
Poor contact in the
not operate
lower lift motor
(C251).
connector terminals.
Defective MPCB.
3-6-34
Causes
Check procedures/corrective measures
With CN5-30 on the MPCB held low, check if
the scanner fan motor 1 operates. If it does,
replace the MPCB.
Check for continuity across the coil. If none,
replace the scanner fan motor 2.
Check for continuity across the connector
terminals. If none, replace them.
With CN5-28 on the MPCB held low, check if
the scanner fan motor 2 operates. If it does,
replace the MPCB.
Check for continuity across the coil. If none,
replace the paper conveying fan motor.
Check for continuity across the connector
terminals. If none, replace them.
With CN3-1 on the MPCB held low, check if
the paper conveying fan motor operates. If it
does, replace the MPCB.
Check for continuity across the coil. If none,
replace the upper lift motor.
Check for continuity across the connector
terminals. If none, replace them.
Check if 24 V DC is output across CN17-11
(+) and CN17-10 (–) on the MPCB right after
the upper cassette is installed. If not, replace
the MPCB.
Check for continuity across the coil. If none,
replace the lower lift motor.
Check for continuity across the connector
terminals. If none, replace them.
Check if 24 V DC is output across CN18-11
(+) and CN18-10 (–) on the MPCB right after
the lower cassette is installed. If not, replace
the MPCB.
Need help?