Removing The Forwarding Pulley - Kyocera Mita DC-2560 Service Manual

Table of Contents

Advertisement

1AH

(1-2) Removing the forwarding pulley

Procedure
1. Removing the primary paper feed unit. (see page 3-3-109)
2. Raise the forwarding pulley retainer in the directions of the arrows as shown in
Figure 3-3-105 and remove it from the primary paper feed unit.
3.Remove the stop ring, pull out the forwarding pulley shaft in the direction of the
arrow as shown (Figure 3-3-106), and remove the forwarding pulley.
Forwarding pulley shaft
4. Refit all the removed parts.
3-3-110
Figure 3-3-105
Forwarding pulley
Figure 3-3-105
Forwarding pulley
retainer
Stop ring