1AH
( 7 ) Detaching and refitting the heat roller claws
Clean or replace the heat roller claws as follows.
Procedure
1. Remove the fixing unit from the machine. (see page 3-3-90)
2. Remove the upper fixing guide plate. (see page 3-3-97)
3. Remove the heat roller claws.
4. Remove the E-ring, and moving the separation claws shaft in the direction of the
arrow 1 from the upper fixing guide plate.
5. Remove the heat roller claws moving it in the direction of the arrow 2.
* Be careful of the claw's leading edge damage, when fitting the heat roller claw.
6. Refit all the removed parts.
3-3-100
Heat roller claw
spring
Upper fixing guide plate
Figure 3-3-95
Heat roller
claw
2
1
Separation claws shaft
E-ring