HVAC
6. Connect the electrical connector at the A/C
refrigerant pressure sensor.
7. Recharge the A/C system. Refer to
Refrigerant
Recovery and Recharging.
8. Perform a leak test on the A/C system. Refer to
Leak Testing.
Service Ports Replacement
Removal Procedure
Tools Required
J
34611-A Valve Core Remover and Installer
1. Recover the refrigerant. Refer to
Refrigerant
Recovery and Recharging.
2. Remove the valve core using J 34611-A.
Installation Procedure
Tools Required
J
34611-A Valve Core Remover and Installer
1. Install the valve core using J 34611-A.
2. Recharge the A/C system. Refer to
Refrigerant
Recovery and Recharging.
3. Test the fitting for leaks. Refer to
Leak Testing.
HVAC System - Manual
1-87
282947
297244
297244