16. Malfunction code
16.5 Solution
16.5.1

C0104: Tray 3/4 feeder transportation motor failure to turn

16.5.2

C0105: Tray 3/4 feeder transportation motor turning at abnormal timing

Transport motor (M25)
Step
Check the M25 connector for proper con-
1
nection and correct as necessary.
Check the connector of M25 for proper
2
drive coupling and correct as necessary.
3
M25 operation check
4
Change M25
5
Change PFTDB
6
Change PRCB
16.5.3

C0202: Tray 1 feeder up/down abnormality

Tray 1 upper limit sensor (PS6)
Tray 1 lift-up motor (M6)
Step
Check the M6 connector for proper connec-
1
tion and correct as necessary.
Check the connector of M6 for proper drive
2
coupling and correct as necessary.
3
PS6 I/O check, sensor check
4
M6 operation check
5
Change M6
6
Change PFTDB
7
Change PRCB
638
Relevant parts
Action
Relevant parts
Action
Field Service Ver. 8.0 Jun. 2008
Paper feed/transport drive board (PFTDB)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
PFTDB CN12PFTDB-6 (LOCK)
Paper feed/transport drive board (PFTDB)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
PFTDB CN4PFTDB-3 (ON)
PFTDB CN18PFTDB-9 (ON)
Location (Electri-
cal component)
V-12
Location (Electri-
cal component)
P-4