Field Service Ver. 8.0 Jun. 2008
6.3.79
Exit motor (M4)
1. Remove the fan motor assy /1.
See the steps 1 to 7 of fusing motor removing procedure.
See P.212
[2]
[1]
[2]
[1]
A00JF2C302DA
[1]
A00JF2C303DA
[2]
A00JF2C304DA
2. Disconnect the connector [1], and
remove the harness from the wire
saddle [2].
3. Remove two screws [1], and remove
the exit motor assy [2].
4. Remove two screws [1], and remove
the exit motor [2].
6. Other
215