16. Malfunction code
Code
Item
CD004 Hard disk access error
CD005 Hard disk error 1
CD006 Hard disk error 2
CD007 Hard disk error 3
CD008 Hard disk error 4
CD009 Hard disk error 5
CD00A Hard disk error 6
CD00B Hard disk error 7
CD00C Hard disk error 8
CD00D Hard disk error 9
CD00E Hard disk error A
CD00F Hard disk data transfer
error
CD010 Hard disk unformat
CD011 Hard disk out of
specifications mounted
CD020 Hard disk verify error
CD030 Hard disk management
information reading error
CD201 File memory mounting
error
CD202 Memory capacity
discrepancy
CD203 Memory capacity
discrepancy 2
CD211 PCI-SDRAM DMA
operation failure
CD212 Compression/extraction
timeout detection
CD231 No Fax memory at FAX
board mounting
CD241 Encryption board setting
error
CD242 Encryption board
mounting error
622
Detection timing
• Unable to communicate between the hard
disk and printer control board (PRCB).
• Hard disk is faulty.
• Data transfer from the hard disk is faulty.
• Unformatted hard disk is connected.
• A hard disk that falls outside the specifica-
tions is connected.
• The data abnormality is detected by the
HDD verify check.
• The machine fails to read administrative
information data saved in the hard disk.
• The file memory is not mounted.
• The file has any abnormality.
• File memory capacity on the printer control
board (PRCB) is not enough.
• File memory capacity necessary for duplex
printing is not enough during duplex unit
mounting.
• File memory capacity on the printer control
board (PRCB) is not enough.
• Hardware related to the transfer of memory
image of the printer control board (PRCB)
fails to respond.
• Hardware related to the BTC compression
function of the printer control board (PRCB)
fails to respond.
• The DIMM for FAX is not mounted during
the FAX board is mounting.
• The FAX board is not mounted when the
FAX board mounting is set ON at Service
Mode.
• Initialization error of the encrypted ASIC is
detected during the machine is starting.
• The faulty of the installation of encrypted
ASIC is detected during the machine is
starting.
Field Service Ver. 8.0 Jun. 2008
Trouble iso-
lation com-
pliant unit
Rank
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C