8. Mechanical adjustment
[1]
[2]
8. Remove the rear cover.
See P.26
9. Remove the FNS control board.
See P.38
[1]
[3]
[1]
76
[3]
A07RF3C525DA
[2]
A07RF2C030DA
[2]
[4]
A07RF3C526DA
Field Service Ver. 7.0 Jun. 2008
5. Open the bypass transfer guide plate
[1].
6. Check to see if the clearance
between the bypass gate [2] and the
bypass transfer plate [3] is within a
standard value when the bypass
gate solenoid turns OFF.
Standard value: A = 3.2 ± 0.5 mm
7. When the value is not within the
standard value, perform the following
adjustment.
10. Remove six screws [1] and remove
the FNS control board mounting
plate [2].
11. Loosen two screws [1] on the bypass
gate solenoid, and then, by referring
to the markings [4], adjust the posi-
tion of SD5 so that the clearance
between the bypass gate [2] and the
bypass transfer plate [3] gets to the
standard value when bypass gate
solenoid turns OFF.