Adjusting The Paper Exit Opening Solenoid - Konica Minolta bizhub C650 Service Manual

Hide thumbs Also See for bizhub C650:
Table of Contents

Advertisement

8. Mechanical adjustment
8.3

Adjusting the paper exit opening solenoid

• Conduct this adjustment when the paper exited to the finishing tray 1 is misaligned.
1. Remove the upper cover/1.
See P.25
2. Remove the upper cover/2.
See P.25
3. Turn ON the main power switch and perform [SD4(paper exit solenoid):ON] in the ser-
vice mode.
See P.68
4. Turn OFF the main power switch.
[2]
[2]
[2]
[1]
78
5. Check to see if the clearance
[1]
6. When the value is not within the
[3]
A07RF3C532DA
7. Remove two screws [1] and remove
[1]
A07RF3C533DA
8. Loosen two screws [1] and move the
9. Tighten two screws [1].
A
A07RF3C534DA
Field Service Ver. 7.0 Jun. 2008
between the plunger [2] of the sole-
noid and the stopper [3] of the
mounting plate is within a standard
value when paper exit opening sole-
noid [1] turns ON.
Standard value: A = 6.5 ± 0.5 mm
standard value, perform the following
adjustment.
paper exit opening solenoid assy [2].
paper exit opening solenoid [2] in
either direction to determine the
proper position.