Field Service Ver. 5.0 Jan. 2008
a
4. If the difference in the width of a falls outside the specified range, make the following
adjustment.
5. Call the Service Mode to the screen.
See P.434 of the main body service manual.
6. Touch [ADF].
7. Touch [Original Stop Position].
3. Check that the difference in the
NOTE
• In the same way place the chart
with the blank side facing up in the
document feed tray in the duplex
mode and make a copy. Check the
difference in the widths of a
between the chart and the second
9J07F3C526DA
sided surface of the copy sample.
8. Touch [Sub Scanning Direction 1-
9. Enter the value from the ten-key pad.
• Adjustable range: -4.0 mm to + 4.0
mm
• If the difference in the widths of a is
greater than the specifications, enter
the + value.
• If the difference in the widths of a is
A01HF3E532DA
smaller than the specifications, enter
the - value.
7. Mechanical adjustment
widths of a between the chart and
the copy sample falls within the
specified range.
Specifications: 0 ± 2 mm
Side] or [Sub Scanning Direction 2-
Side].
(Press the [+/-] key to change the +/-
code.)
(in 1-mm increments)
A01HF3E525DA