3. Other
3.3
Disassembly/Assembly procedure
3.3.1
Large capacity unit
[1]
[1]
[3]
[4]
[2]
8
[2]
A03NF2C502DA
[2]
A03NF2C501DA
[1]
A03NF2C503DA
Field Service Ver. 3.0 May 2007
1. Remove the LCT from the main body
to remove three screws [1]. Remove
the lower right cover/4 [2] from the
main body.
2. Remove two screws [1] to remove
the lower right cover/2 [2] from the
main body.
3. Disconnect the connector [1], the
screw on the earth wire [2], and the
cord clamp [3].
NOTE
• When reinstalling the harness, be
sure not to let the harness be
inserted in the wire saddle [4].