Field Service Ver. 7.0 Jun. 2008
4.3.13
Stacker unit
• Be sure to conduct this operation with 2 personnel.
• Be careful not to let finisher fall down when removing finisher from the
main body and pulling out the stacker unit from finisher. It may cause the
injury.
A. For FS-517/FS-518
5
1. Remove the finisher.
See P.31
2. Remove the front door.
See P.26
3. Remove the rear cover.
See P.26
4. Remove the left cover.
See P.27
5. Pull out the stacker unit.
[2]
[3]
CAUTION
[1]
A07RF2C013DA
[2]
[1]
A07RF2C014DA
6. Remove two connectors (CN22 and
CN23) [1] from the FNS drive board.
7. Remove the harness from the three
wire saddles [2].
8. Remove the C-clip [1] and the shaft
[2] and separate the coupling arm
[3].
4. Other