Field Service Ver. 8.0 Jun. 2008
Code
Item
CC151 ROM contents error upon
startup (MSC)
CC152 ROM contents error upon
startup (scanner)
CC153 ROM contents error upon
startup (PRT)
CC155 Finisher ROM error
6
CC156 ADF ROM error
CC157 Finisher ROM error (RU)
6
CC158 Finisher ROM error (ZU)
CC163 ROM contents error (PRT) • The wrong model of firmware is detected in
CC164 ROM contents error
(MSC)
CC170 Dynamic link error during
starting (AP0)
CC171 Dynamic link error during
starting (AP1)
CC172 Dynamic link error during
starting (AP2)
CC173 Dynamic link error during
starting (AP3)
CC174 Dynamic link error during
starting (AP4)
CC180 Dynamic link error during
starting (LDR)
CC181 Dynamic link error during
starting (IBR)
CC182 Dynamic link error during
starting (IID)
CC183 Dynamic link error during
starting (IPF)
CC184 Dynamic link error during
starting (IMY)
CC165 ROM contents error
(ADF)
CD002 JOB RAM save error
Detection timing
• A fault is detected in a sequence of ROM
contents check of the MSC (PRCB) during
starting
• A fault is detected in a sequence of ROM
contents check of the IPB during starting.
• A fault is detected in a sequence of ROM
contents check of the mechanical control
board (MFPB) during starting.
See P.119 of the FS-517/518/608 service
manual.
See P.73 of the FS-519/PK-510/OT-602 ser-
vice manual.
See P.22 of the JS-504 service manual.
See P.62 of the DF-611/610 service manual.
See P.119 of the FS-517/518/608 service
manual.
See P.55 of the ZU-603 service manual.
the engine during the initial connection to
the engine is being checked.
• The wrong model of firmware is detected in
the MFP board when the main power switch
is turned ON.
• A dynamic link error occurs in the program
on the MFP board due to an insufficient
memory space available, a ROM fault, or
other reason when the main power switch is
turned ON.
See P.62 of the DF-611/610 service manual.
• The error in save of job data to the memory/
hard disk and its read error are detected.
16. Malfunction code
Trouble iso-
lation com-
Rank
pliant unit
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
621