8. Utility Mode
(6) Audit Log Settings
3
• This is displayed only when the function enhanced version 2 or later firmware is installed.
• It will be displayed when the following setting shows that switch No.42 is set to [01] at
HEX assignment.
[Service Mode] → [System 2] → [Software Switch Setting]
Functions
• Selects whether to keep logs of operations and access made by users and service
• To set whether to overwrite existing logs.
Use
• To ensure security, this settings is used to keep logs of operations and access includ-
• Audit logs are saved in HDD and NVRAM.
Setting/
• The default setting is No.
Procedure
NOTE
• After selecting "Yes", the main power switch must be turned OFF and ON so
• When ON is selected in [Administrator Settings] → [Security Settings] →
<Overwrite>
• Set whether to allow or restrict overwriting existing logs when saving audit logs.
• The default setting is Restrict.
• To erase audit logs, press [Erase Audit Log].
(7) Restrict Fax TX
Functions
• To set whether or not to prohibit sending fax.
Use
• To prohibit sending fax.
Setting/
• The default setting is OFF.
Procedure
420
3
engineers.
ing security settings changes, authentication, and job executions by users and ser-
vice engineers.
Yes
that the new setting takes effect.
[Enhanced Security Mode], this setting is automatically set to "Yes."
Allow
ON
Field Service Ver. 8.0 Jun. 2008
"No"
"Restrict"
"OFF"