6.3.76
Fusing pressure retraction motor (M29)
1. Open the PWB box.
See P.172
[1]
A00JF2C290DA
[1]
A00JF2C291DA
[3]
[1]
[2]
A00JF2C292DA
7. Remove two screws [1], and take out
the shaft metal plate [2].
8. Remove two screws [1], and remove
the registration motor [2].
2. Disconnect the connector [1].
3. Remove two screws [2], and remove
the fusing pressure retraction motor
[3].
6. Other
211