Field Service Ver. 8.0 Jun. 2008
6.3.29

Original glass moving unit

A. Removal procedure
1. Remove the IR left cover.
See P.113
2. Remove the IR front cover.
See P.114
3. Remove the original glass.
See P.114
4. Remove the original glass moving motor.
See P.202
5. Remove the glass step sheet.
See P.133
[1]
[3]
[4]
[1]
[2]
[2]
[1]
A00JF2C416DA
[4]
[3]
[1]
[2]
[2]
A00JF2C417DA
6. Remove four screws [1], and remove
the original glass moving unit cover
[2].
7. Remove the C-ring [1] and the collar
[2] one each, and remove the belts
[3] of both sides of the original glass
mounting unit out of the gear [4].
NOTE
• Be sure the direction of the collar
[2] to be as shown in the left illus-
tration when mounting it.