Symbol WS5000 Series System Reference Manual page 308

Hide thumbs Also See for WS5000 Series:
Table of Contents

Advertisement

8-76
WS 5000 Series System Reference
MU idle timeout — It is the time for which each MU's details ( which are associated) will retian in the switch
database. This helps MUs in PSP mode not ot get removed from the database till the timeout value expires.
The default value is 30 minutes.
Syntax
set muidletimeout <muIdleTimeout value>
Parameters
The time duration for which the MU should be idle
muIdleTimeout
Example
WS5000.(Cfg)> set muidletimeout 88
Setting the MU Idle Timeout value....
Status: Success.
System information...
System Name
Description
Switch Location
Software Ver.
Licensed to
Copyright
Serial Number
Number of Licenses
Max Access Ports
Max Mobile Clients
MU Idle Timeout value
Active Switch Policy
Emergency Switch Policy
Switch Uptime
Global RF stats
# of Unassigned Access Ports : 0
CLI AutoInstall Status
WS5000.(Cfg)>
set rfthreshold
Configuration (Cfg) Context
Syntax
set rfthreshold <Type> <Thresholdname> <Thresholdvalue / reset>
Parameters
Type
Placeholder for the type of RF threshold. It can be either AP, MU or Switch.
Thresholdname
Placeholder for the threshold associated with each of the threshold type mentioned
above.
Thresholdvalue
Place holder for the value that can be associated with each of the threshold name.
Example
WS5000.(Cfg)> set rfthreshold mu pps 100
Success.
: WS5000
: WS5000 Wireless Network
: US
: 2.1.0.0-014B
: Symbol Technologies
: Copyright (c) 2000-2006.
: 00A0F865A8E0
: 8
: 8
: 4096
: 88
seconds
: Default Wireless Switch Policy
: Not defined
: 01d:07h:30m
: Disabled
: Enabled