Reinstalling The Power Distribution Modules After Installing The Mx2020 Router With A Pallet Jack; Figure 54: Reinstalling An Ac Power Distribution Module - Juniper MX2020 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX2020:
Table of Contents

Advertisement

MX2020 3D Universal Edge Router Hardware Guide
Reinstalling the Power Distribution Modules After Installing the MX2020 Router with a Pallet
Jack
100
To reinstall the AC or DC PDMs, follow this procedure for each PDM (see
page 100
and
Figure 55 on page
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
For a AC-powered router, move the AC circuit breaker on the power source to the off
2.
(
O
) position. For a DC-powered router, move the DC circuit breaker on the power
source to the off (
) position.
O
We recommend this precaution even though the PDMs are not connected to power
sources.
Take each PDM to be installed out of its electrostatic bag, and identify the slot on the
3.
PDM where it will be connected.
Turn the DC power switch to the off (
4.
PDM that is being reinstalled.
Using both hands, grasp the two handles and slide the PDM partway into the chassis.
5.
Align both locking levers with the openings in the chassis, and simultaneously close
6.
them to fully seat the PDM.
Tighten both captive screws on the locking levers.
7.

Figure 54: Reinstalling an AC Power Distribution Module

NOTE:
The three-phase delta or wye AC PDM terminal blocks will be flipped
depending on which slot the PDMs gets plugged into.
101):
) position on all PSMs that are zoned for the
O
Copyright © 2013, Juniper Networks, Inc.
Figure 54 on