DC Power Cable Specifications for the MX2020 Router

360
CAUTION:
You must ensure that power connections maintain the proper
polarity. The power source cables might be labeled
their polarity. There is no standard color coding for DC power cables. The
color coding used by the external DC power source at your site determines
the color coding for the leads on the power cables that attach to the terminal
studs on each PDM.
WARNING:
For field-wiring connections, use copper conductors only.
CAUTION:
Power cords and cables must not block access to device
components or drape where people could trip on them.
MX2020 DC Power Distribution Module Description on page 49
MX2020 DC Power Supply Module Description on page 51
Connecting Power to a DC-Powered MX2020 Router with Power Distribution Modules
on page 131
Installing MX2020 DC Power Supply Modules on page 134
Replacing an MX2020 DC Power Distribution Module Cable on page 273
Connecting an MX2020 DC Power Distribution Module Cable on page 274
DC Power Cable Specifications for the MX2020 Router on page 360
The cable lugs attach to the terminal studs of each PDM (see

Figure 153: DC Power Cable Lug

End view
0.27
0.55
2 holes
0.09
0.25
0.63
CAUTION:
Before router installation begins, a licensed electrician must attach
a cable lug to the grounding and power cables that you supply. A cable with
an incorrectly attached lug can damage the router.
(+)
Figure 153 on page
All measurements in inches