Replacing an MX2020 Three-Phase Delta AC Power Cord

Copyright © 2013, Juniper Networks, Inc.
Using a number 2 Phillips (+) screwdriver, tighten the four captive screws on the metal
16.
AC wiring compartment.
Verify that the AC power cord is not touching or blocking access to router components,
17.
and that it does not drape where people could trip on it.
Remove the ESD grounding strap from the ESD points on the chassis. Connect the
18.
strap to an approved site ESD grounding point. See the instructions for your site.
Connect the AC power cord plug to the power source.
19.
Switch on the customer site circuit breakers to provide voltage on the AC power cord.
20.
Remove the ESD grounding strap from the approved site ESD grounding point. See
21.
the instructions for your site. Reconnect the strap to one of the ESD points on the
chassis.
Verify that the LED on the PDM faceplate is lit steadily, indicating that the AC terminal
22.
block is receiving power.
Switch the power switch on all the PSMs to the on (
23.
the router components.
Preventing Electrostatic Discharge Damage to an MX2020 Router on page 320
MX2020 Three-Phase Delta AC Power Distribution Module Description on page 42
MX2020 Three-Phase Wye AC Power Distribution Module Description on page 44
MX2020 Three-Phase Delta and Wye AC Power Distribution Module LEDs on page 46
Connecting AC Power to a MX2020 Router with Three-Phase Delta AC Power
Distribution Modules on page 117
Troubleshooting the MX2020 Power Subsystem on page 202
Replacing an MX2020 Three-Phase Delta AC Power Cord on page 283
MX2020 AC Power Cord Specifications on page 370
MX2020 Three-Phase Delta AC Power Distribution Module Specifications on page 369
The MX2020 router has either one redundant PDM or two redundant PDMs. An AC power
cord on a redundant PDM is hot-insertable and hot-removable. When a redundant PDM
is powered down, the other PDM automatically assumes the entire electrical load for the
router. If you have only one PDM, you must power off the system before removing the
AC power cord.
Removing an MX2020 Three-Phase Delta AC Power Cord on page 284
1.
Installing an MX2020 Three-Phase Delta AC Power Cord on page 286
2.
Chapter 13: Replacing MX2020 Router Hardware Components
) position to provide power to
|
283

Advertisement

Table of Contents
loading

Table of Contents