Dell PowerConnect M6348 Cli Reference Manual page 996

Command line interface guide
Hide thumbs Also See for PowerConnect M6348:
Table of Contents

Advertisement

Sample Type: delta
Startup Alarm: rising
Rising Threshold: 8700000
Falling Threshold: 78
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
Field
Alarm
OID
Last Sample Value
Interval
Sample Type
Startup Alarm
Rising Threshold
Falling Threshold
Rising Event
Falling Event
Owner
996
Description
Alarm index.
Monitored variable OID.
The statistic value during the last sampling period. For example, if the sample
type is delta, this value is the difference between the samples at the beginning and
end of the period. If the sample type is absolute, this value is the sampled value at
the end of the period.
The interval in seconds over which the data is sampled and compared with the
rising and falling thresholds.
The method of sampling the variable and calculating the value compared against
the thresholds. If the value is absolute, the value of the variable is compared
directly with the thresholds at the end of the sampling interval. If the value is
delta, the value of the variable at the last sample is subtracted from the current
value, and the difference compared with the thresholds.
The alarm that may be sent when this entry is first set. If the first sample is greater
than or equal to the rising threshold, and startup alarm is equal to rising or rising
and falling, then a single rising alarm is generated. If the first sample is less than
or equal to the falling threshold, and startup alarm is equal falling or rising and
falling, then a single falling alarm is generated.
A sampled statistic threshold. When the current sampled value is greater than or
equal to this threshold, and the value at the last sampling interval is less than this
threshold, a single event is generated.
A sampled statistic threshold. When the current sampled value is less than or
equal to this threshold, and the value at the last sampling interval is greater than
this threshold, a single event is generated.
The event index used when a rising threshold is crossed.
The event index used when a falling threshold is crossed.
The entity that configured this entry.