Examples
# Enable the remote stable alarm on OLT 3/0/1.
<Sysname> system-view
[Sysname] interface olt 3/0/1
[Sysname-Olt3/0/1] alarm remote-stable enable

alarm software-error enable

Syntax
alarm software-error enable
undo alarm software-error enable
View
FTTH view
Default Level
2: System level
Parameters
None
Description
Use the alarm software-error enable command to enable the software error alarm of the system.
Use the undo alarm software-error enable command to disable the software error alarm of the
system.
The system generates a software error alarm when a signal error, DA abnormity (that is, data access
abnormity) error, or memory allocation failure occurs.
By default, the software error alarm is enabled.
Examples
# Enable the software error alarm in the EPON system.
<Sysname> system-view
[Sysname] ftth
[Sysname-ftth] alarm software-error enable

monitor enable

Syntax
monitor enable
undo monitor enable
View
FTTH view
3-19